authorized agent Fluke 115C true RMS digital multimeter

Fluke 115C true RMS digital multimeter
Specifications
Maximum voltage between any terminal and earth ground
 600 V
Surge protection
 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital:  6,000 counts, updates 4 per second
Bar graph
 33 segments, updates 32 per second
Operating Temperature
 -10 °C to + 50 °C
Storage Temperature
 -40 °C to + 60 °C
Battery type
 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
 400 hours typical, without backlight

 

Accuracy Specifications
DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω , off > 250 Ω ; detectsopens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0  Ω / 0.1 Ω
Range/Resolution:  6.000 k Ω / 0.001 k Ω
Range/Resolution:  60.00 k Ω / 0.01 k Ω
Range/Resolution:  600.0 k Ω / 0.1 k Ω
Range/Resolution:  6.000 M Ω / 0.001 M Ω
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 M Ω / 0.01 M Ω
Accuracy:  5 % + 2
Diode Test
Range/Resolution:  2.00 V / 0.001 V
Accuracy:  0.9% + 2
Capacitance
Range/Resolution:  1000 nF / 1 nF
Range/Resolution:  10.00 µF / 0.01 µF
Range/Resolution:  100.0 µF / 0.1 µF
Range/Resolution:  9999 µF / 1 µF
Range/Resolution:  100 µF to 1000 µF
Accuracy:  1.9% + 2
Range/Resolution:  > 1000 µF
Accuracy:  5% + 20%
Lo-Z Capacitance
Range:  1 nF to 500 µF
Accuracy:  10% + 2 typical
AC amps true-rms (45 Hz to 500Hz)
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.5% + 3
 20 A overload for 30-seconds max
DC amps
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.0% + 3
 20 A overload for 30-seconds max
Hz (V or A input)2
Range/Resolution:  99.99 Hz / 0.01 Hz
Range/Resolution:  999.9 Hz / 0.01 Hz
Range/Resolution:  9.999 kHz / 0.001 kHz
Range/Resolution:  50 kHz / 0.01 kHz
Accuracy:  0.1% + 2