High Accutacy Wall Mounted Ultrosonic Flow Meter Measurement Kit UFLO2000F1,Water,Oil ,Plant effluent,Chemicals,etc

High Accutacy Wall Mounted Ultrosonic

Measurement of Flow  UFLO2000F1 ,DN15-6000mm

Applicable medium: Water, sea water,fuel oil and other single, uniform and stable liquid which can conduct ultrasonic 


High Accutacy Wall Mounted Ultrosonic Flow Meter Measurement Kit UFLO2000F1,Water,Oil ,Plant effluent,Chemicals,etc

§1.Charactaristic

1.1 Features

a. Linearity: 0.5%, Repeatability: 0.2%, Accuracy:±1%

b. Several type transducers for selection, measuring pipe size is from DN15mm to DN6000mm

c. Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.

d. Powerful Recording Function, record the totalizer data of the last 64 days/64 monthes/5 years.

 

1.2 Flow measurement principle

The transit time measured about velocity of the liquid in the pipe, show as follows:

 

High Accutacy Wall Mounted Ultrosonic Flow Meter Measurement Kit UFLO2000F1,Water,Oil ,Plant effluent,Chemicals,etc

1.3. Optional transducer

a. TS-1 clamp-on type transducer, pipe size from DN15-100mm

 

b. TM-1 clamp-on type transducer, pipe size from DN50-1000mm

 

c. TL-1 clamp-on type transducer, pipe size from DN300-6000mm

1.4. Typical application

The wall-mounting flow meter can be applied to a wide range of pipe flow measurements. Applicable liquids include pure liquids as well as liquid with small quantity of tiny particles.

Examples are:

a. Water (hot water, chilled water, city water, sea water, waste water, etc.);

b. Sewage with small particle content;

c. Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.);

d. Chemicals (alcohol, acids, etc.);

e. Plant effluent;

f. Beverage, liquid food;

g. Ultra-pure liquids;

h. Solvents and other liquids

 

1.5. Product Identification

Each set of the flow meter has a unique product identification number or  ESN (electronic serial number) written into the software that can only be modified with a special tool by the manufacturer. In case of any hardware failure, please provide this number which is located on menu window M61 when contacting the manufacturer.

 

1.6. Specifications

 

Items Specifications
Main unit Accuracy Better than ±1%
Repeatability Better than 0.2%
Principle Transit-time measuring principle
Measurement

Period

500ms
Display LCD with backlight, display accumulated flow/heat, instantaneous flow/heat, velocity, time etc.
  Output Analogue output: 4-20mA or 0-20mA current output. Impedance 0∼1kW. Accuracy 0.1%.
    OCT output: Frequency signal (1~9999HZ)
Relay output: over 20 source signal (no signal, reverse flow etc.)
    RS485 serial port
  Input Three analogue input
Three-wire PT100 resistor input (optional)
Other functions Automatically record the totaliser data of the last 64 days / 64 months / 5 years;

The power-on time and corresponding flow rate of the last 64 power on and off events. Allow manual or automatic flow loss compensation

The instrument working status of the last 64 days

pipe material Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed
Size 15-6000mm
Straight pipe section In the upstream it must be beyond 10D, in the downstream it must be beyond 5D, in the upstream the length must be beyond 30D from the access of the pump. (D stands for pipe diameter)
Liquid Types Water, sea water, industrial sewage, acid & alkali liquid, alcohol, beer, all kinds of oils which can transmit ultrasonic single uniform liquid
Temperature Standard: -30 degree – 90 degree ,High-temperature:-30degree – 160 degree
Turbidity Less than 10000ppm, with a little bubble
  Flow Direction Bi-directional measuring, net flow/heat measuring
Environment Temperature Main Unit: -30 degree – 80 degree
Transducer: -40 degree -110 degree , Temperature transducer: select on enquiry
Humidity Main Unit: 85% RH
Transducer: water-immersible, water depth less than 3m
Cable Twisted Pair Line, standard length of 20m, can be extended to 500m (not recommended); Contact the manufacturer for longer cable requirement.

RS-485 interface, transmission distance up to 1000m

Power Supply AC220V or DC24V
Power Consumption Less than 1.5W
Protocols MODBUS, M-BUS, Fuji extended protocol and other factory protocol

 

 

§2. Installation 

 

2.1. Wiring diagram

High Accutacy Wall Mounted Ultrosonic Flow Meter Measurement Kit UFLO2000F1,Water,Oil ,Plant effluent,Chemicals,etc

 

2.2. Wiring diagram of transducer installation

High Accutacy Wall Mounted Ultrosonic Flow Meter Measurement Kit UFLO2000F1,Water,Oil ,Plant effluent,Chemicals,etc